C1113 (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
When FS-539SD is installed
Contents
Trouble type | C1113: Stopper drive motor malfunction (When FS-539SD is installed) |
Rank | B |
Trouble detection condition | The stopper home sensor (PS106) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the stopper drive motor (M104) is energized. |
Trouble isolation | -StapleCenter -Stapling/Half-Fold/Tri-Fold |
Relevant electrical parts | -Stopper drive motor (M104) -Stopper home sensor (PS106) -SD control board (SDCB) -FS control board (FSCB) |
Procedure
- Check the connector between M104-SDCB J10 for proper connection and correct as necessary.
- Check the connector of M104 for proper drive coupling and correct as necessary.
- Check the connector between PS106-SDCB J10 for proper connection and correct as necessary.
- PS106 I/O check, sensor check
- Control signal: SDCB J10-5 (ON)
- Location of electrical component: FS-539/FS-539SD 2-P
- M104 operation check
- Control signal: SDCB J10-6 to 9
- Location of electrical component: FS-539/FS-539SD 2-P
- Replace M104. (Part# A3EPPP5600)
- Replace SDCB. (Part# A3ERPP6J03)
- Replace FSCB. (Part# AAR4PP8201)
When FS-540SD is installed
Contents
Trouble type | C1113: Stopper drive motor malfunction (When FS-540SD is installed) |
Rank | B |
Trouble detection condition | The stopper home sensor (PS106) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the stopper drive motor (M104) is energized. |
Trouble isolation | StapleCenter Stapling/Half-Fold/Tri-Fold |
Relevant electrical parts | -Stopper drive motor (M104) -Stopper home sensor (PS106) -SD control board (SDCB) -FS control board (FSCB) |
Procedure
- Check the connector between M104-SDCB J10 for proper connection and correct as necessary.
- Check the connector of M104 for proper drive coupling and correct as necessary.
- Check the connector between PS106-SDCB J10 for proper connection and correct as necessary.
- PS106 I/O check, sensor check
- Control signal: SDCB J10-5 (ON)
- Location of electrical component: FS-540/FS-540SD 2-P
- M104 operation check
- Control signal: SDCB J10-6 to 9
- Location of electrical component: FS-540/FS-540SD 2-P
- Replace M104. (Part# A3EPPP5600)
- Replace SDCB. (Part# A3ERPP6J03)
- Replace FSCB. (Part# AAR5PPD401)