C6001 (bizhub 750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C6001: DF related configuration error 1 |
Rank | C |
Trouble detection condition | Inconsistency in the configuration with the installed DF is detected on the main body. |
Trouble isolation | – |
Relevant electrical parts | -DF control board (DFCB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the type of the installed DF and replace it if it is a wrong one.
- Check the connector between DFCB CN12-relay CN3DF-BASEB CN9E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace DFCB. (Part# AAMPH00105)
- Replace CPUB. (Part# ACV7H02P02)
- Replace BASEB. (Part# ACV7H02101)