C7162 (bizhub 750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7162: Tray 2 vertical transport motor failure |
Rank | B |
Trouble detection condition | After starting the motor, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | -Tray 2 vertical transport motor (M23) -Base board (BASEB) |
Procedure
- Check the connector between M23-BASEB CN31E for proper connection and correct as necessary.
- Check the connector of M23 for proper drive coupling and correct as necessary.
- M23 conduction check.
- Control signal: BASEB CN31E-5 to 8
- Location of electrical component: 23-K
- Replace M23. (Part# A61DM10000)
- Replace BASEB. (Part# ACV7H02101)