C8103 (bizhub 750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C8103: Lift up mechanism trouble (Upward movement) |
Rank | B |
Trouble detection condition | The DF lift-up upper limit sensor (PS2) is not turned ON (blocked) after a lapse of a given time after the DF lift-up motor (M5) moves up (is turned forward). |
Trouble isolation | DF |
Relevant electrical parts | -DF lift-up motor (M5) -DF lift-up upper limit sensor (PS2) -DF control board (DFCB) |
Procedure
- Check the connector between M5-DFCB CN9 for proper connection and correct as necessary.
- Check the connector of M5 for proper drive coupling and correct as necessary.
- Check the connector between PS2-DFCB CN5A for proper connection and correct as necessary.
- PS2 I/O check, sensor check
- Control signal: DFCB CN5A-6 (ON)
- Location of electrical component: DF 8-J
- M5 load check
- Check code: 60
- Multi code: 97, 98
- Control signal: DFCB CN9-1 to 5
- Location of electrical component: DF 5-C
- Replace M5. (Part# AAMPR70700)
- DFCB ICP5 conduction check
- Replace DFCB. (Part# AAMPH00105)