C5611 (bizhub C368/C308/C258)
Contents
Trouble type | C5611: PH EEPROM communication error |
Rank | C |
Trouble detection condition | Results of two readings of the EEPROM data disagree with each other. |
Trouble isolation | – |
Relevant electrical parts | • Front side board (FRB) • PH unit • MFP board (MFPB) |
Procedure
- Reboot the machine.
- Check the connector between FRB CN5-PH unit for proper connection and correct as necessary.
- Check the connector between FRB CN2-MFPB CN10E for proper connection and correct as necessary.
- Replace FRB. (Part# A7PUH00500)
- Replace the PH unit. (Part# A7PUR71200)
- Replace MFPB. (Part# A7PUH02123)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.16.12 (Link to the Field Service Manual)