C1105 (bizhub 360i/300i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
When FS-539 or FS-539SD is installed
Contents
Trouble type | C1105: Bundle eject motor drive malfunction (When FS-539 or FS-539SD is installed) |
Rank | B |
Trouble detection condition | The gripper home sensor (PS18) is not turned OFF (blocked) or ON (unblocked) even after the set period of time has elapsed after the bundle eject motor (M10) is energized. |
Trouble isolation | – |
Relevant electrical parts | -Bundle eject motor (M10) -Gripper home sensor (PS18) -FS control board (FSCB) |
Procedure
- Check the connector between M10-relay CN7A-FSCB J13 for proper connection and correct as necessary.
- Check the connector of M10 for proper drive coupling and correct as necessary.
- Check the connector between PS18-relay CN7A-FSCB J13 for proper connection and correct as necessary.
- PS18 I/O check, sensor check
- Control signal: FSCB J13-13 (ON)
- Location of electrical component: FS-539/FS-539SD 16-C
- M10 operation check
- Control signal: FSCB J13-1 to 2
- Location of electrical component: FS-539/FS-539SD 17-C
- Replace M10. (Part# A87GPP1400)
- FSCB F8 conduction check
- Replace FSCB. (Part# AAR4PP8201)