C9702 (bizhub 4750i/4050i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C9702: Back side reading device cable break detection |
Rank | A |
Trouble detection condition | The cable between the DF CIS module (DF CIS) and the base board (BASEB) is break. |
Trouble isolation | Scanner |
Relevant electrical parts | -Flat cable -DF CIS module (DF CIS) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between DFCISRYB CN2-BASEB CN5 for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the flat cable. (Part# A93EN11H00)
- Replace the DF CIS module assy. (Part# A93EH00901)
- Replace CPUB. (Part# ACT9H01003)
- Replace BASEB.
4750i (Part# ACT9H02013)
4050i (Part# ACT9H02002)