P-36 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Malfunction type | Media sensor failure 2 |
Malfunction code | P-36 |
Malfunction detection timing | – When starting the machine, or the lower front door or the right door is opened and closed, ultrasonic waves sensor error is detected. – Measure the received voltages when CLK is output and when CLK is not output, and the values are determined to be faulty. |
Relevant parts | – Envelope detection board/TX (ENVDB/TX) – Envelope detection board/RX (ENVDB/RX) – Envelope detection relay board (ENVDRB)Paper feed/transport – – — drive board (PFTDB) – CPU board (CPUB) – Base board (BASEB) |
Procedure
- Open the right door and check if there is any foreign matter between ENVDB/RX and ENVDB/TX.
- Check the connector between ENVDB/RX CN491-relay CN166B-PFTDB CN30 for proper connection and correct as necessary.
- Check the connector between ENVDB/TX CN490-ENVDRB CN2 for proper connection and correct as necessary.
- Check the connector between ENVDRB CN1-relay CN145A-PFTDB CN30 for proper connection and correct as necessary.
- Replace ENVDB/RX.
- Replace ENVDB/TX.
- Replace ENVDRB.
- Check the connector between PFTDB CN4-BASEB CN7E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- PFTDB F42 conduction check.
- Paper feed/transport drive board (PFTDB)
- CPU board (CPUB)
- Base board (BASEB)