C2255: Color developing motor failure to turnC2256: Color developing motor turning at abnormal timing
Rank
B
Trouble detection condition
C2255: The control circuit detects motor failure to turn while the motor is turning.C2256: The control circuit detects motor turning while the motor remains stationary.
Trouble isolation
–
Relevant electrical parts
Color developing motor (M10)CPU board (CPUB)Base board (BASEB)
Procedure
Check the connector between M10-BASEB CN24E for proper connection and correct as necessary.
Check the connector of M10 for proper drive coupling and correct as necessary.
Check CPUB for proper installation and correct as necessary.