Trouble type | C2559: Cyan TCR sensor adjustment failureC255A: Magenta TCR sensor adjustment failureC255B: Yellow TCR sensor adjustment failureC255C: Black TCR sensor adjustment failure |
Rank | B |
Trouble detection condition | TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value. |
Trouble isolation | – |
Relevant electrical parts | Imaging unit/C,M,Y,KCPU board (CPUB)Base board (BASEB) |
Procedure
- Reinstall the imaging unit.
- Check the connector between the imaging unit/C-relay CN5-BASEB CN14E for proper connection and correct as necessary. (C2559)
- Check the connector between the imaging unit/M-relay CN8-BASEB CN14E for proper connection and correct as necessary. (C255A)
- Check the connector between the imaging unit/Y-relay CN7-BASEB CN14E for proper connection and correct as necessary. (C255B)
- Check the connector between the imaging unit/K-relay CN6-BASEB CN14E for proper connection and correct as necessary. (C255C)
- Check CPUB for proper installation and correct as necessary.
- Replace the corresponding imaging unit.
- Replace CPUB.
- Replace BASEB.