Trouble type | C5360: Clean unit fan failure to turn (When CU-204 is installed) (Europe models only) |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | Exhaust fan/1 (FM1)Exhaust fan/2 (FM2)Exhaust fan/3 (FM3)Clean unit drive board (CUDB)CPU board (CPUB)Base board (BASEB) |
Procedure
- Check the connector between CUDB CN1-relay CN35-BASEB CN25E for proper connection and correct as necessary.
- Check the connector between FM1-relay CN101-CUDB CN2 for proper connection and correct as necessary.
- Check the connector between FM2-relay CN102-CUDB CN2 for proper connection and correct as necessary.
- Check the connector between FM3-relay CN103-CUDB CN2 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- FM1 load check
- Check code: 42
- Multi code: 9, 10
- Control signal: CUDB CN2-1 (REM), CUDB CN2-3 (LOCK)
- Location of electrical component: 27-L
- FM2 load check
- Check code: 42
- Multi code: 9, 10
- Control signal: CUDB CN2-4 (REM), CUDB CN2-6 (LOCK)
- Location of electrical component: 28-L
- FM3 load check
- Check code: 42
- Multi code: 9, 10
- Control signal: CUDB CN2-7 (REM), CUDB CN2-9 (LOCK)
- Location of electrical component: 28-L
- Replace the defective fan. (FM1 / FM2 / FM3)
- Replace CUDB.
- Replace CPUB.
- Replace BASEB.