C7613 (C4751i)

You are here:

Contents

Trouble typeC7613: Power line A19 error
RankC
Trouble detection conditionThe fuse detection unit detected an error for a predetermined time.
Trouble isolation
Relevant electrical partsMachine cooling fan (FM1)Toner suction fan (FM2)Base board (BASEB)

Procedure

  1. BASEB F2E conduction check
  2. Check the connector between FM1-relay CN23-BASEB CN19E for proper connection and correct as necessary.
  3. Check the connector between FM2-relay CN10-BASEB CN24E for proper connection and correct as necessary.
  4. Replace FM1.
  5. Replace FM2.
  6. Replace BASEB.

(Link to the Field Service Manual)