CE001, CE003, CE004, CE005, CE006, CE007, CE009, CE011 (C4751i)

You are here:

Contents

Trouble typeCE001: Abnormal message queueCE003: Task errorCE004: Event errorCE005: Memory access errorCE006: Header access errorCE007: DIMM initialize errorCE009: Memory resource shortage errorCE011: Config. file access error at startup of FW
RankC
Trouble detection conditionCPU board (CPUB) is faulty.
Trouble isolation
Relevant electrical partsCPU board (CPUB)Base board (BASEB)

Procedure

  1. Check the connectors on BASEB for proper connection and correct as necessary.
  2. Replace CPUB.
  3. Replace BASEB.

(Link to the Field Service Manual)