C1196 (bizhub C554e/C454e)
(1)Contents
| Trouble type | Center fold roller motors malfunction <When FS-534+SD-511 is installed>  Tri-fold guide motors malfunction <When FS-535+SD-512 is installed>  | |
| Trouble code | C1196 | |
| Rank | B | |
| Detection timing | <When FS-534+SD-511 is installed>  The guide home sensor (PS7) is not blocked or unblocked even after the set period of time has elapsed after the center fold roller motor (M6) is turned ON. <When FS-535+SD-512 is installed> The tri-fold guide home sensor (PS7) is not not blocked or unblocked even after the set period of time has elapsed after the tri-fold guide motor (M6) is turned ON.  | |
| Trouble isolation | Half-Fold/Tri-Fold Center Stapling | |
| Relevant electrical parts | <When FS-534+SD-511 is installed>  • Center fold roller motor (M8) • Guide home sensor (PS7) • SD drive board (SDDB) • FS control board (FSCB) <When FS-535+SD-512 is installed> • Tri-fold guide motor (M6) • Tri-fold guide home sensor (PS7) • SD drive board (SDDB) • FS control board (FSCB)  | 
(2)ProcedureWhen FS-534+SD-511 is installed
| Step | Action | Control signal | Location of electrical components | 
| 1 | Check the connector between M8-SDDB J8 for proper connection, and correct as necessary. | – | – | 
| 2 | Check the connector of M8 for proper drive coupling, and correct as necessary. | – | – | 
| 3 | Check the connector between PS7-SDDB J9 for proper connection, and correct as necessary. | – | – | 
| 4 | PS7 I/O check, sensor check | SDDB J9-6 (ON) | SD-511 4-G | 
| 5 | M8 operation check | SDDB J8-11 to 14 | SD-511 2 to 3-F to G | 
| 6 | Replace M8 (Part# A3ERPP3N00) | – | – | 
| 7 | Replace SDDB (Part# A3ERPP6J03) | – | – | 
| 8 | Replace FSCB (Part# A3EPPPBE01) | – | – | 
- Link to the wiring diagram (N.3.9 SD-511)
 - Link to the layout drawings for related parts by each trouble code (S.50.1 SD-511)
 
When FS-535+SD-512 is installed
| Step | Action | Control signal | Location of electrical components | 
| 1 | Check the connector between M6-SDDB J9 for proper connection, and correct as necessary. | – | – | 
| 2 | Check the connector of M6 for proper drive coupling, and correct as necessary. | – | – | 
| 3 | Check the connector between PS7-SDDB J9 for proper connection, and correct as necessary. | – | – | 
| 4 | PS7 I/O check, sensor check | SDDB J9-6 (ON) | SD-512 4-G | 
| 5 | M6 operation check | SDDB J9-7 to 10 | SD-512 3-F to G | 
| 6 | Replace M6 (Part# A3ERPP5R00) | – | – | 
| 7 | Replace SDDB (Part# A3ERPP6J03) | – | – | 
| 8 | Replace FSCB (Part# A2Y1H10002) | – | – | 
- Link to the wiring diagram (N.3.12 SD-512)
 - Link to the layout drawings for related parts by each trouble code (S.50.2 SD-512)
 
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.6.37 (Link to the Field Service Manual)