C2554 (bizhub C360i/C300i/C250i)
Contents
| Trouble type | C2554: Abnormally high toner density detected magenta TCR sensor | 
| Rank | B | 
| Trouble detection condition | The TC ratio of the toner determined by the toner replenishment control is detected to be the predetermined value or over for consecutive times. | 
| Trouble isolation | – | 
| Relevant electrical parts | • Developing unit/C,M,Y,K  • Toner cartridge/C,M,Y,K • Expansion control board (EXCB) • CPU board (CPUB) • Base board (BASEB)  | 
Procedure
- Reinstall the developing unit.
 - Reinstall the toner cartridge.
 - Check the connector between the developing unit/C-relay CN251-relay CN248-EXCB CN6EX for proper connection and correct as necessary.
 - Check the connector between EXCB CN1EX-BASEB CN11E for proper connection and correct as necessary.
 - Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
 - Check CPUB for proper installation and correct as necessary.
 - Replace the corresponding developing unit.
 - Replace EXCB. (Part# AA2JH00500)
 - Replace CPUB. (Part# AA2JH02N06)
 - Replace BASEB. (Part# AA2JH02005)
 
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.8.8 (Link to the Field Service Manual)