C2355 (bizhub 368e/308e)

You are here:

Contents

Trouble typeC2355: Transfer belt cleaner cooling fan failure to turn
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Transfer belt cleaner cooling fan (FM2)
• MFP board (MFPB)

 Procedure

  1. Check the connector between FM2-relay CN115-relay CN141-MFPB CN15EB for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM2 load check
    • Check code: 42
    • Multi code: 2
    • Control signal: MFPB CN15EB-3 (REM), MFPB CN15EB-5 (LOCK)
    • Location of electrical component: 9-C
  4. Replace FM2. (Part# 4139M10000)
  5. Replace MFPB. (Part# AA6VH02101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.9.1 (Link to the Field Service Manual)