C2557 (bizhub 368/308)

You are here:

Contents

Trouble typeC2557: Abnormally low toner density detected black TCR sensor
RankB
Trouble detection conditionWhen sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper.
Trouble isolation
Relevant electrical parts• Developing unit
• Toner cartridge
• Toner empty sensor/K (PS31)
• Toner cartridge motor/K (M25)
• Toner supply motor/K (M6)
• Front side board (FRB)
• MFP board (MFPB)

 Procedure

  1. Perform image troubleshooting procedure if image density is low.
  2. Reinstall developing unit.
  3. Reinstall toner cartridge.
  4. Check the connector between the developing unit -FRB CN13 for proper connection and correct as necessary.
  5. Check the connector between FRB CN1, CN3-MFPB CN4E, CN11E for proper connection and correct as necessary.
  6. M25 operation check
    • Control signal: MFPB CN30E-1 to 4
    • Location of electrical component: 16-C
  7. M6 operation check
    • Control signal: MFPB CN30E-5 to 8
    • Location of electrical component: 17-C
  8. If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them.
  9. Replace the developing unit. (Part# A7U403D)
  10. Replace FRB. (Part# A9HJH00501)
  11. Replace MFPB. (Part# A9HJH02102)

NOTICE

  • Link to the wiring diagram (bizhub 368/308)
  • Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.10.3 (Link to the Field Service Manual)