C5304 (bizhub 558/458)
Contents
| Trouble type | C5304: Fusing power supply cooling fan failure to turn (bizhub 558) | 
| Rank | B | 
| Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. | 
| Trouble isolation | – | 
| Relevant electrical parts | • Fusing power supply cooling fan (FM12)  • MFP board (MFPB)  | 
Procedure
- Check the connector between FM12-relay CN146-MFPB CN15E for proper connection and correct as necessary.
 - Check the fan for possible overload and correct as necessary.
 - FM12 operation check
- Control signal: MFPB CN15E<A>-16 (REM), MFPB CN15E<A>-18 (LOCK)
 - Location of electrical component: 558 16-C, 458 20-C
 
 - Replace FM12. (Part# 4139M10000)
 - Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)
 
NOTICE
- Link to the wiring diagram (bizhub 558/458)
 
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.17.2 (Link to the Field Service Manual)