C6912 (bizhub 558/458)
Contents
Trouble type | C6912: DSC board bus check NG2-1 (When SC-508 is installed) |
Rank | C |
Trouble detection condition | When DSC bus check (back side) detects an error. |
Trouble isolation | – |
Relevant electrical parts | • DSC board 2 (DSCB/2; SC-508) • Dual scan image processing board (DSIPB) • MFP board (MFPB) |
Procedure
- Correct the harness connection of DSCB/2 if faulty.
- Correct the harness connection of DSIPB if faulty.
- Replace DSCB/2. (Part# N/A)
- Replace DSIPB. (Part# A7PUH02A01)
- Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.