C3723 (bizhub 958/808)
Contents
Trouble type | C3723: Fusing abnormally high temperature detection (pressure) (bizhub 958, bizhub PRO 958 only) |
Rank | A |
Trouble detection condition | Detected temperature of the pressure roller thermistor/2 (TH3) goes beyond a given temperature for a given period of time consecutively. |
Trouble isolation | – |
Relevant electrical parts | • Fusing unit • Pressure roller thermistor/2 (TH3) • IH power supply unit (IHPU) • Noise filter (NF1) • Pressure roller power supply unit (PRPU) • MFP board (MFPB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the open/close operation of the upper right door.
- Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary.
- Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary.
- Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary.
- Replace the fusing unit. ( 958)A796R71422 )( 808)A795R72922 )
- Replace IHPU. (958)( A796M40B00 )(808)( A8KNM40A02 )
- Replace PRPU. ( A796M40500 )
- Replace MFPB. ( A796H02003)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
(Link to the Field Service Manual) K.3.9.11.