C5304 (bizhub 958/808)

You are here:

Contents

Trouble typeC5304: IH power supply cooling fans failure to turn
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• IH power supply cooling fan (FM10)
• MFP board (MFPB)

 Procedure

  1. Check the connector between FM10-relay CN293-MFPB CN18E for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM10 operation check
    • Control signal: MFPB CN18E-13 (DRIVE), MFPB CN18E-14 (LOCK)
    • Location of electrical component: 15-K
  4. Replace FM10. (Part# 9J03M10000)
  5. MFPB F7E conduction check
  6. Replace MFPB. (Part# A796H02003)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.11.2 (Link to the Field Service Manual)