C5610 (bizhub 958/808)
Contents
Trouble type | C5610: PH LD drive communication error |
Rank | C |
Trouble detection condition | LD drive write data and read data disagree with each other a predetermined number of consecutive times. |
Trouble isolation | – |
Relevant electrical parts | • PH unit • PH relay board (PHRYB) • MFP board (MFPB) |
Procedure
- Reboot the machine.
- Check the connector between the PH unit-PHRYB CN8 for proper connection and correct as necessary.
- Check the connector between PHRYB CN1-MFPB CN6E for proper connection and correct as necessary.
- Replace the PH unit. (Part# A796R70500)
- Replace PHRYB. (Part# A796H00300)
- Replace MFPB. (Part# A796H02003)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.11.10 (Link to the Field Service Manual)