C7141 (bizhub C360i/C300i/C250i)
Contents
| Trouble type | C7141: Fusing pressure motor failure | 
| Rank | C | 
| Trouble detection condition | After starting the motor, an error is detected for the malfunction detection signal. | 
| Trouble isolation | – | 
| Relevant electrical parts | • Fusing pressure motor (M11) • Expansion control board (EXCB) | 
Procedure
- Check the connector between M11-relay CN112-EXCB CN14EX for proper connection and correct as necessary.
- Check the connector of M11 for proper drive coupling and correct as necessary.
- M11 conduction check.- Control signal: EXCB CN14EX-11 to 14
- Location of electrical component: 6-P
 
- Replace M11. (Part# A161M10300)
- Replace EXCB. (Part# AA2JH00500)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.13.12 (Link to the Field Service Manual)