C2350 (bizhub C4050i/C3350i)
Contents
| Trouble type | C2350: Toner suction fan failure to turn | 
| Rank | B | 
| Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. | 
| Trouble isolation | – | 
| Relevant electrical parts | • Toner suction fan (FM2)  • CPU board (CPUB) • Base board (BASEB)  | 
Procedure
- Check the connector between FM2-relay CN10-BASEB CN18E for proper connection and correct as necessary.
 - Check the fan for possible overload and correct as necessary.
 - Check CPUB for proper installation and correct as necessary.
 - FM2 load check
- Check code: 42
 - Multi code: 3
 - Control signal: BASEB CN18E-12 (REM), BASEB CN18E-14 (LOCK)
 - Location of electrical component: 3-C
 
 - Replace FM2. (Part# A93EM10600)
 - Replace CPUB. (Part# A93EH01004)
 - Replace BASEB. (Part# A93EH02007)
 
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.7.3 (Link to the Field Service Manual)