C0107 (bizhub C658/C558/C458)
Contents
Trouble type | C0107: Tray 3/transfer LCT vertical transport motor’s turning at abnormal timing (When PC-115, PC-215, or PC-415 is installed) | |
Rank | B | |
Trouble detection condition | •The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. •The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. | |
Trouble isolation | – | |
Relevant electrical parts | <When PC-115 or PC-215 is installed>Tray 3 vertical transport motor (M112)PC control board (PCCB) | |
<When PC-415 is installed>Vertical transport motor (M132)PC control board (PCCB) |
Procedure
When PC-115 or PC-215 is installed
- Check the connector between M112-PCCB CN5 for proper connection and correct as necessary.
- Check the connector of M112 for proper drive coupling and correct as necessary.
- M112 operation check
- Control signal: PCCB CN5-13 (CW/CCW)
- Location of electrical component: PC-115/PC-215 3 to 4-C
- Replace M112. (Part# A2XMM11000)
- Replace PCCB. (PC-115 Part# A2XMH00101/ PC-215 Part# A2XMH00201)
NOTICE
When PC-415 is installed
- Check the connector between M132-PCCB CN5 for proper connection and correct as necessary.
- Check the connector of M132 for proper drive coupling and correct as necessary.
- M132 operation check
- Control signal: PCCB CN5-13 (CW/CCW)
- Location of electrical component: PC-415 4-J
- Replace M132. (Part# A2XMM11000)
- Replace PCCB. (Part# A2XMH00301)
NOTICE
- Link to the wiring diagram (PC-415)
Please review all part numbers for accuracy and current version.
K.3.8.3 (Field Service Manual Link)