C1081 (bizhub 554e/454e)
ontents
Trouble type | SD communication error | |
Trouble code | C1081 | |
Rank | C | |
Detection timing | <When FS-534+SD-511 is installed> <When FS-535+SD-512 is installed> | When a communication error is detected between the FS control board (FSCB) and the SD control board (SDDB). |
Trouble isolation | Half-Fold/Tri-Fold/Center Stapling | |
Relevant electrical parts | • SD drive board (SDDB) • FS control board (FSCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. | – | – |
2 | Rewrite the firmware. | – | – |
3 | Replace SDDB (SD-511/SD-512) SDDB SD-512/SD-511 (Part# A3ERPP6J03) | – | – |
4 | Replace FSCB (FS-534/FS-535) FSCB FS-533 (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2)) FS-534 (Part# A3EPPPBE01) FS-535 (Part# A2Y1H10002) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.18. C1081)
Document Information ID D0001134262 Revise ID R000004
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.6.5 (Link to the Field Service Manual)