How Can We Help?

20-21 (bizhub C287/C227)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

JAM typeMisfeed at vertical transport section (tray 3)
JAM code20-21
JAM detection timing<When PC-114 or PC-214 is installed>
The tray 2 vertical transport sensor (PS19) is not turned ON (unblocked) even after the lapse of a given period of time after the tray 3 vertical transport sensor (PS113) is turned ON by a paper.
<When PC-414 is installed>
The tray 2 vertical transport sensor (PS19) is not turned ON (unblocked) even after the lapse of a given period of time after the LCT vertical transport sensor (PS133) is turned ON by a paper.
Paper jam of a sheet of paper left at the vertical transport section results, if a sheet of paper is determined to exist at a position detected when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
Misfeed processing locationRight door
Relevant parts<When PC-114 or PC-214 is installed>
-Transport motor (M1)
-Tray 3 vertical transport motor (M112)
-Tray 2 vertical transport clutch (CL2)
-Tray 2 vertical transport sensor (PS19)
-Tray 3 vertical transport sensor (PS113)
-MFP board (MFPB)
-PC control board (PCCB)
<When PC-414 is installed>
-Transport motor (M1)
-Vertical transport motor (M132)
-Tray 2 vertical transport clutch (CL2)
-Tray 2 vertical transport sensor (PS19)
-LCT vertical transport sensor (PS133)
-MFP board (MFPB)
-PC control board (PCCB)

 Procedure

 When PC-114 or PC-214 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS113 I/O check, sensor checkPCCB CN4-14 (ON)PC-114/PC-214 5-C
3PS19 I/O check, sensor checkMFPB CN5E<B>-16 (ON)12-C
4CL2 operation checkMFPB CN5E<B>-13 (ON)11-C
5M112 operation checkPCCB CN5-9 to 16PC-114/PC-214 3 to 4-C
6M1 operation checkMFPB CN11E-4 (REM)MFPB CN11E-7 (LOCK)3-C
7MFPB F13E, F21E conduction check
8Replace MFPB. (Part# A797H02118)
9Replace PCCB. (PC-114 Part# A7VAH00100 / PC-214 Part# A7VAH00200)

 When PC-414 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS133 I/O check, sensor checkPCCB CN4-14 (ON)PC-414 7-J
3PS19 I/O check, sensor checkMFPB CN5E<B>-16 (ON)12-C
4CL2 operation checkMFPB CN5E<B>-13 (ON)11-C
5M132 operation checkPCCB CN5-9 to 16PC-414 4-J
6M1 operation checkMFPB CN11E-4 (REM)MFPB CN11E-7 (LOCK)3-C
7MFPB F13E, F21E conduction check
8Replace MFPB. (Part# A797H02118)
9Replace PCCB. (Part# A7VAH00300)

K.1.7.2 (Link to the Field Service Manual)