JAM typeMisfeed at fusing/paper exit section
JAM code32-05
JAM detection timing-The paper exit sensor (PS39) is not turned ON (unblocked) even after the lapse of a given period of time after the paper has turned ON (unblocked) fusing loop sensor/Fr (PS41) and fusing loop sensor/Rr (PS42).
-The paper exit sensor (PS39) is not turned OFF (blocked) even after the lapse of a given period of time after PS3 turns ON (unblock) by a paper.
Paper jam of a sheet of paper left at the exit section results, if the paper exit sensor (PS39) is turned ON (unblocked) when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
Misfeed processing locationUpper right door
Relevant parts-Exit motor (M4)
-Fusing motor (M30)
-ADU transport motor/1 (M31)
-Reverse motor (M33)
-Gate switch solenoid (SD1)
-Paper exit sensor (PS39)
-Fusing loop sensor/Fr (PS41)
-Fusing loop sensor/Rr (PS42)
-ADU paper passage sensor/1 (PS47)
-Paper feed/transport drive board (PFTDB)
-MFP board (MFPB)

 Procedure

StepActionControl signalLocation of electrical component
1Initial check items
2PS39 I/O check, sensor checkPFTDB CN2-12 (ON)5-P
3PS41 I/O check, sensor checkPFTDB CN5-3 (ON)8-P
4PS42 I/O check, sensor checkPFTDB CN5-6 (ON)9-P
5PS47 I/O check, sensor checkPFTDB CN28-3 (ON)6-P
6M4 load check
-Check code: 27
-Multi code: 1, 2, 3, 4
MFPB CN19E-13 to 1610-K
7M30 load check
-Check code: 45
-Multi code: 1, 2, 3, 4, 5, 6
MFPB CN28E-1 (DC24V)MFPB CN28E-4 (REM)MFPB CN28E-7 (LOCK)7-K
8M31 load check
-Check code: 85
-Multi code: 1, 2, 3, 4
PFTDB CN28-14 to 178-P
9M33 load check
-Check code: 84
-Multi code: 1, 2, 3, 4, 5, 6, 7, 8
MFPB CN19E-9 to 1210-K
10SD1 load check
-Check code: 83
-Multi code: 0
MFPB CN19E-7 (DRIVE)10-K
11PFTDB F10 conduction check
12Replace PFTDB. (Part# A795H00200)
13MFPB F13E or F16E conduction check
14Replace MFPB. (Part# A8JEH02002)