How Can We Help?
66-01, 66-11, 66-21 (bizhub 360i/300i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
JAM type | Misfeed at DF turnover section | |
JAM code | 66-01, 66-11, 66-21 | |
JAM detection timing | 66-01: <When DF-632 is installed> The document registration sensor (PS3) is not turned ON (unblocked) even after the lapse of a given period of time after the reverse registration operation started. | |
66-11: <When DF-632 is installed> The document registration sensor (PS3) is not turned OFF (blocked) even after the lapse of a given period of time after PS3 has turned ON (unblocked) after the reverse registration operation started. | ||
66-21: <When DF-632 is installed> The document reading sensor (PS4) is not turned ON even after the lapse of a given period of time after the document registration sensor (PS3) is turned ON (unblocked) after the reverse registration operation started. | ||
Misfeed processing location | -Left cover -Re-feeding opening | |
Relevant parts | -Document reading motor (M1) -Registration motor (M3) -Document registration sensor (PS3) -Document reading sensor (PS4) -DF control board (DFCB) |
Procedure
Step | Action | Control signal | Location of electrical component |
---|---|---|---|
1 | Initial check items | – | – |
2 | PS4 I/O check, sensor check | DFCB J10-3 (ON) | DF-632 2-G |
3 | PS3 I/O check, sensor check | DFCB J14-12 (ON) | DF-632 5-G |
4 | M1 load check Check code: 60 Multi code: 34, 35, 36, 37, 38, 39 | DFCB J7-1 to 4 | DF-632 2-B |
5 | M3 load check Check code: 60 Multi code: 17, 18, 19, 20 | DFCB J6-1 to 4 | DF-632 3-B |
6 | DFCB F6 conduction check | – | – |
7 | Replace DFCB. (Part# AAYHPP0200) | – | – |