How Can We Help?

66-03, 66-13, 66-23, 66-33 (bizhub 360i/300i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

JAM typeMisfeed at DF transport section
JAM code66-03, 66-13, 66-23, 66-33
JAM detection timing66-03:
<When DF-632 or DF-714 is installed>
The after separate sensor (PS2) is not turned OFF (unblocked) even after the lapse of a given period of time after PS2 has turned ON (blocked).
66-13:
<When DF-632 or DF-714 is installed>
The document registration sensor (PS3) is not turned ON (unblocked) even after the lapse of a given period of time after the after separate sensor (PS2) has turned ON (blocked).
66-23:
<When DF-632 or DF-714 is installed>
The document registration sensor (PS3) is not turned OFF (blocked) even after the lapse of a given period of time after PS3 has turned ON (unblocked).
66-33:
<When DF-632 is installed>
The document reading sensor (PS4) is not turned ON even after the lapse of a given period of time after the document registration sensor (PS3) has turned ON (unblocked).
<When DF-714 is installed>
The document reading sensor (PS6) is not turned ON even after the lapse of a given period of time after the document registration sensor (PS3) has turned ON (unblocked).
Paper jam of a sheet of paper left at the DF transfer section results, if the registration sensor (PS3) is turned ON (unblocked) when the main power switch is turned ON, a DF left cover is opened and closed, or a misfeed or malfunction is reset.
Misfeed processing locationLeft cover
Relevant parts<When DF-632 is installed>
-Document reading motor (M1)
-Document feed motor (M2)
-Registration motor (M3)
-After separate sensor (PS2)
-Document registration sensor (PS3)
-Document reading sensor (PS4)
-DF control board (DFCB)
<When DF-714 is installed>
-Document reading motor (M1)
-Document feed motor (M2)
-Registration motor (M3)
-After separate sensor (PS2)
-Registration sensor (PS3)
-Document reading sensor (PS6)
-DF control board (DFCB)

Procedure

When DF-632 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS2 I/O check, sensor checkDFCB J14-8 (ON)DF-632 6-G
3PS3 I/O check, sensor checkDFCB J14-12 (ON)DF-632 5-G
4PS4 I/O check, sensor checkDFCB J10-3 (ON)DF-632 2-G
5M1 load check
Check code: 60
Multi code: 34, 35, 36, 37, 38, 39
DFCB J7-1 to 4DF-632 2-B
6M2 load check
Check code: 60
Multi code: 1, 2, 3, 5, 6
DFCB J5-1 to 4DF-632 2-B
7M3 load check
Check code: 60
Multi code: 17, 18, 19, 20
DFCB J6-1 to 4DF-632 3-B
8DFCB F3, F4, F5 conduction check
9Replace DFCB. (Part# AAYHPP0200)

When DF-714 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS2 I/O check, sensor checkDFCB J14-8 (ON)DF-714 6-G
3PS3 I/O check, sensor checkDFCB J14-12 (ON)DF-714 4-G
4PS6 I/O check, sensor checkDFCB J10-3 (ON)DF-714 2-G
5M1 load check
Check code: 60
Multi code: 34, 35, 37, 40
DFCB J7-1 to 4DF-714 1-B
6M2 load check
Check code: 60
Multi code: 1, 2, 3, 4, 5, 6
DFCB J5-1 to 4DF-714 1 to 2-B
7M3 load check
Check code: 60
Multi code: 17, 18, 20, 21, 22, 23
DFCB J6-1 to 4DF-714 2-B
8DFCB F3, F4, F5 conduction check
9Replace DFCB. (Part# AAMNPP4901)

(Link to the Field Service Manual)

Table of Contents