How Can We Help?

66-13 (bizhub C360i/C300i/C250i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

JAM typeMisfeed at DF transport section
JAM code66-13
JAM detection timing<When DF-632 or DF-714 is installed> 
The document registration sensor (PS3) is not turned ON (unblocked) even after the lapse of a given period of time after the after separate sensor (PS2) has turned ON (blocked).
Misfeed processing locationLeft cover
Relevant parts<When DF-632 is installed>
• Document reading motor (M1) 
• Document feed motor (M2) 
• Registration motor (M3) 
• After separate sensor (PS2) 
• Document registration sensor (PS3) 
• Document reading sensor (PS4) 
• DF control board (DFCB)
<When DF-714 is installed>
• Document reading motor (M1) 
• Document feed motor (M2) 
• Registration motor (M3) 
• After separate sensor (PS2) 
• Document registration sensor (PS3) 
• Document reading sensor (PS6) 
• DF control board (DFCB)

Procedure

When DF-632 is installed

StepActionControl signalLocation of electrical component
1Initial check items 
2PS2 I/O check, sensor checkDFCB J14-8 (ON)DF-632 6-G
3PS3 I/O check, sensor checkDFCB J14-12 (ON)DF-632 5-G
4PS4 I/O check, sensor checkDFCB J10-3 (ON)DF-632 2-G
5M1 load checkCheck code: 60Multi code 34, 35, 36, 37, 38, 39DFCB J7-1 to 4DF-632 2-B
6M2 load checkCheck code: 60Multi code: 1, 2, 3, 5, 6DFCB J5-1 to 4DF-632 2-B
7M3 load checkCheck code: 60Multi code: 17, 18, 19, 20DFCB J6-1 to 4DF-632 3-B
8DFCB F3, F4, F5 conduction check
9Replace DFCB. (DF-632 Part# AAYHPP0200)

When DF-714 is installed

StepActionControl signalLocation of electrical component
1Initial check items 
2PS2 I/O check, sensor checkDFCB J14-8 (ON)DF-714 6-G
3PS3 I/O check, sensor checkDFCB J14-12 (ON)DF-714 4-G
4PS6 I/O check, sensor checkDFCB J10-3 (ON)DF-714 2-G
5M1 load checkCheck code: 60Multi code: 34, 35, 37, 40DFCB J7-1 to 4DF-714 1-B
6M2 load checkCheck code: 60Multi code: 1, 2, 3, 4, 5, 6DFCB J5-1 to 4DF-714 1 to 2-B
7M3 load checkCheck code: 60Multi code: 17, 18, 20, 21, 22, 23DFCB J6-1 to 4DF-714 2-B
8DFCB F3, F4, F5 conduction check
9Replace DFCB. (DF-714 Part# AAMNPP4901)

L.1.8.3 (Link to the Field Service Manual)

Table of Contents