66-13 (bizhub C364e/C284e/C224e)
Contents
JAM type | DF transport section | |
JAM code | 66-13 | |
Detection timing | <When DF-624 is installed> The document registration sensor (PS3) is not unblocked after a lapse of a given time after the after separate sensor (PS2) is blocked. | |
<When DF-701 is installed> The registration sensor (PS3) is not unblocked after a lapse of a given time after the after separate sensor (PS2) is blocked. | ||
Misfeed processing location | Left cover | |
Relevant parts | <When DF-624 is installed> -Document reading motor (M1) -Document feed motor (M2) -Registration motor (M3) -After separate sensor (PS2) -Document registration sensor (PS3) -Document reading sensor (PS4) -DF control board (DFCB) | |
<When DF-701 is installed> -Document reading motor (M1) -Document feed motor (M2) -Registration motor (M3) -After separate sensor (PS2) -Registration sensor (PS3) -Document reading sensor (PS6) -DF control board (DFCB) |
(2)ProcedureWhen DF-624 is installed
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
2 | PS2 I/O check, sensor check | DFCB J14-8 (ON) | DF-624 6-G |
3 | PS3 I/O check, sensor check | DFCB J14-12 (ON) | DF-624 5-G |
4 | PS4 I/O check, sensor check | DFCB J10-3 (ON) | DF-624 2-G |
5 | M1 operation check | DFCB J7-1 to 4 | DF-624 2-B |
6 | M2 operation check | DFCB J5-1 to 4 | DF-624 2-B |
7 | M3 operation check | DFCB J6-1 to 4 | DF-624 3-B |
8 | DFCB F4, F5 conduction check | – | – |
9 | Replace DFCB (Part# A3CFPP5Q00) | – | – |
- Link to the wiring diagram (N.2.2 DF-624)
When DF-701 is installed
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
2 | PS2 I/O check, sensor check | DFCB J14-8 (ON) | DF-701 6-G |
3 | PS3 I/O check, sensor check | DFCB J14-12 (ON) | DF-701 4-G |
4 | PS6 I/O check, sensor check | DFCB J10-3 (ON) | DF-701 2-G |
5 | M1 operation check | DFCB J7-1 to 4 | DF-701 1-B |
6 | M2 operation check | DFCB J5-1 to 4 | DF-701 1 to 2-B |
7 | M3 operation check | DFCB J6-1 to 4 | DF-701 2-B |
8 | DFCB F4, F5 conduction check | – | – |
9 | Replace DFCB (Part# A3CEPP4900) | – | – |
- Link to the wiring diagram (N.2.1 DF-701)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.9.3 (Link to the Field Service Manual)