How Can We Help?

72-15 (bizhub C759/C659)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

JAM typeMisfeed at FS transport section
JAM code72-15
JAM detection timing<When FS-536 or FS-536SD is installed>
The saddle exit sensor (PS5) is not turned OFF even after the set period of time has elapsed after it is turned ON.
<When FS-537 or FS-537SD is installed>
The SD discharge sensor (PS35) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper.
Misfeed processing locationFront door
Relevant parts<When FS-536 or FS-536SD is installed>
-Saddle exit sensor (PS5)
-FS control board (FSCB)
<When FS-537 or FS-537SD is installed>
-SD discharge sensor (PS35)
-FS control board (FSCB)

 Procedure

 When FS-536 or FS-536SD is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS5 I/O check, sensor checkFSCB J5-2 (ON)FS-536/FS-536SD 16-K
3Replace FSCB. (Part# A87GPP0V00)

 When FS-537 or FS-537SD is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS35 I/O check, sensor checkFSCB J15-7 (ON)FS-537/FS-537SD 15 to 16-K to L
3Replace FSCB. (Part# A87HPP9M01)

L.1.10.3 (Link to the Field Service Manual)

Table of Contents