How Can We Help?

72-16 (bizhub 958/808)

You are here:

Contents

JAM typeMisfeed at FS transport section
JAM code72-16
JAM detection timing<When FS-536 or FS-536SD is installed>
The FNS entrance sensor (PS4) is not turned ON even after the set period of time has elapsed after the RU transport sensor (PS60) is turned ON (blocked) by the paper.
<When FS-537 or FS-537SD is installed>
The FNS entrance sensor (PS34) is not turned ON even after the set period of time has elapsed after the RU transport sensor (PS60) is turned ON (blocked) by the paper.
Misfeed processing locationHorizontal conveyance cover
Relevant parts<When FS-536 or FS-536SD is installed>
• RU transport sensor (PS60)
• FNS entrance sensor (PS4)
• FS control board (FSCB)
<When FS-537 or FS-537SD is installed>
• RU transport sensor (PS60)
• FNS entrance sensor (PS34)
• FS control board (FSCB)

 Procedure

 When FS-536 or FS-536SD is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS60 I/O check, sensor checkFSCB J6-7 (ON)FS-536/FS-536SD 12-K
3PS4 I/O check, sensor checkFSCB J4<B>-9 (ON)FS-536/FS-536SD 15-C
4Replace FSCB. (Part# A87GPP0V00)

 When FS-537 or FS-537SD is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS60 I/O check, sensor checkFSCB J8<B>-11 (ON)FS-536/FS-536SD 12-K
3PS34 I/O check, sensor checkFSCB J8<A>-5 (ON)FS-536/FS-536SD 15-C
4Replace FSCB. (Part# A87HPP9M01)