72-17 (bizhub 958/808)
Contents
JAM type | Misfeed at FS transport section | ||
JAM code | 72-17 | ||
JAM detection timing | <When FS-536 or FS-536SD is installed> The FNS entrance sensor (PS4) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper. | ||
<When FS-537 or FS-537SD is installed> The FNS entrance sensor (PS34) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper. | |||
Misfeed processing location | Front door | ||
Relevant parts | <When FS-536 or FS-536SD is installed> • FNS entrance sensor (PS4) • FS control board (FSCB) | ||
<When FS-537 or FS-537SD is installed> • FNS entrance sensor (PS34) • FS control board (FSCB) |
Procedure
When FS-536 or FS-536SD is installed
Step | Action | Control signal | Location of electrical component |
---|---|---|---|
1 | Initial check items | – | – |
2 | PS4 I/O check, sensor check | FSCB J4<B>-9 (ON) | FS-536/FS-536SD 15-C |
3 | Replace FSCB. (Part# A87GPP0V00) | – | – |
- Link to the wiring diagram (FS-536/FS-536SD)
When FS-537 or FS-537SD is installed
Step | Action | Control signal | Location of electrical component |
---|---|---|---|
1 | Initial check items | – | – |
2 | PS34 I/O check, sensor check | FSCB J8<A>-5 (ON) | FS-537/FS-537SD 7-D |
3 | Replace FSCB. (Part# A87HPP9M01) | – | – |
- Link to the wiring diagram (FS-537/FS-537SD)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.10.5 (Link to the Field Service Manual)