72-23 (bizhub 754e/654e)

You are here:

Contents

JAM typeFS transport section
JAM code72-23
Detection timing <When FS-534 is installed>
The sub tray exit sensor (PS8) is not blocked even after the set period of time has elapsed after it unblocked.
<When FS-535 is installed>
The sub tray exit sensor (PS8) is not blocked even after the set period of time has elapsed after it unblocked.
Misfeed processing locationFront door
Relevant parts<When FS-534 is installed>
• Sub tray exit sensor (PS8)
• FS control board (FSCB)
<When FS-535 is installed>
• Sub tray exit sensor (PS8)
• FS control board (FSCB)

 (2)ProcedureWhen FS-534 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS8 I/O check, sensor checkFSCB J9<B>-6 (ON)FS-534 9-C
3Replace FSCB (Part# A3EPPPBE01)

When FS-535 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS8 I/O check, sensor checkFSCB CN24-10 (ON)FS-535 8-L
3Replace FSCB (Part# A2Y1H10002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.1.10.12 (Link to the Field Service Manual)