How Can We Help?

72-40 (bizhub 558/458/368/308)

You are here:

Contents

JAM typeMisfeed at ZU section
JAM code72-40
JAM detection timing<When FS-537+ZU-609 or FS-537SD+ZU-609 is installed>
The FNS middle sensor (PS36) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper.
Misfeed processing locationFront door
Relevant parts<When FS-537+ZU-609 or FS-537SD+ZU-609 is installed>
• ZU transport motor (M500)
• Folding guide motor (M501)
• FNS middle sensor (PS36)
• ZU drive board (ZUDB)
• FS control board (FSCB)

 Procedure

 When FS-537+ZU-609 or FS-537SD+ZU-609 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS36 I/O check, sensor checkFSCB J12<A>-10 (ON)FS-537/FS-537SD 16-D
3M500 operation checkZUDB CN6-1 to 6ZU-609 1 to 2-B
4M501 operation checkZUDB CN6-9 to 12ZU-609 2-B
5ZUDB ICP1 or ICP2 conduction check.
6Replace ZUDB. (Part# A63GH00100)
7Replace FSCB. (Part# A87HPP9M01)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.1.16.14 (Link to the Field Service Manual)