72-84 (bizhub C754/C654)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| JAM type | SD staple section | ||
| JAM code | 72-84 | ||
| Detection timing | <When FS-535+SD-512 is installed> The center staple /fold sensor (PS9) does not turn ON even after the set period of time has elapsed after the center-staple operation started. | ||
| Misfeed processing location | -Front door -Stacker unit | ||
| Relevant parts | <When FS-535+SD-512 is installed> -Center staple /fold home sensor (PS9) -SD drive board (SDDB) -FS control board (FSCB) |
(2)ProcedureWhen FS-535+SD-512 is installed
| Step | Action | Control signal | Location of electrical component |
| 1 | Initial check items | – | – |
| 2 | PS9 I/O check, sensor check | SDDB J4-8 (ON) | SD-512 3-B |
| 3 | Replace SDDB (Part# A3ERPP6J03) | – | – |
| 4 | Replace FSCB (Part# A2Y1H10002) | – | – |
- Link to the wiring diagram (N.2.9 Saddle sticher SD-512)
K.1.10.33 (Link to the Field Service Manual)