72-86 (bizhub 360i/300i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
When FS-539SD is installed
Contents
JAM type | Misfeed at SD transport section (When FS-539SD is installed) |
JAM code | 72-85 |
JAM detection timing | The SD entrance sensor (PS101) is not turned ON (blocked) even after the lapse of a given period of time after the leading edge of the paper has turned ON the saddle exit sensor (PS5). |
Misfeed processing location | -Front door -Stacker unit |
Relevant parts | -SD entrance sensor (PS101) -Saddle exit sensor (PS5) -SD control board (SDCB) -FS control board (FSCB) |
Procedure
Step | Action | Control signal | Location of electrical component |
---|---|---|---|
1 | Initial check items | – | – |
2 | PS5 I/O check, sensor check | FSCB J5-2 (ON) | FS-539/FS-539SD 16-K |
3 | PS101 I/O check, sensor check | SDCB J4-3 (ON) | FS-539/FS-539SD 5-L |
4 | Replace SDCB. (Part# A3ERPP6J03) | – | – |
5 | Replace FSCB. (Part# AAR4PP8201) | – | – |