How Can We Help?

72-87 (bizhub 360i/300i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

When FS-539SD is installed

Contents

JAM typeMisfeed at SD transport section (When FS-539SD is installed)
JAM code72-87
JAM detection timingThe center staple/fold stacker paper detect sensor (PS103) is not turned ON even after the lapse of a given period of time after the leading edge of the paper has turned ON the SD entrance sensor (PS101).
Misfeed processing location-Front door
-Stacker unit
Relevant parts-SD transport motor (M101)
-SD entrance sensor (PS101)
-Center staple/fold stacker paper detect sensor (PS103)
-SD control board (SDCB)
-FS control board (FSCB)

Procedure

StepActionControl signalLocation of electrical component
1Initial check items
2PS101 I/O check, sensor checkSDCB J4-3 (ON)FS-539/FS-539SD 5-L
3PS103 I/O check, sensor checkSDCB J7-12 (ON)FS-539/FS-539SD 5-P
4M101 operation checkSDBC J5-8 to 11FS-539/FS-539SD 3-L
5Replace SDCB.
(Part# A3ERPP6J03)
6Replace FSCB.
(Part# AAR4PP8201)

(Link to the Field Service Manual)

Table of Contents