72-86 (bizhub 958/808)
Contents
JAM type | Misfeed at SD transport section | ||
JAM code | 72-86 | ||
JAM detection timing | <When FS-536SD or FS-537SD is installed> The SD entrance sensor (PS1) is not turned OFF (unblocked) even after the set period of time has elapsed after PS1 turns ON (block). | ||
Misfeed processing location | Front door | ||
Relevant parts | <When FS-536SD or FS-537SD is installed> • SD entrance sensor (PS1) • SD control board (SDCB) • FS control board (FSCB) |
Procedure
When FS-536SD or FS-537SD is installed
Step | Action | Control signal | Location of electrical component |
---|---|---|---|
1 | Initial check items | – | – |
2 | PS1 I/O check, sensor check | SDCB J4-8 (ON) | FS-536/FS-536SD 5-LFS-537/FS-537SD 4-K |
3 | Replace SDCB. (FS-536SD/FS-537SD)(Part# A3ERPP6J03) | – | – |
4 | Replace FSCB. (FS-536SD Part# A87GPP0V00 /FS-537SD Part# A87HPP9M01) | – | – |
- Link to the wiring diagram (FS-536/FS-536SD)
- Link to the wiring diagram (FS-537/FS-537SD)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.10.22 (Link to the Field Service Manual)