How Can We Help?

92-01, 92-02, 92-04, 92-40 (bizhub C750i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

JAM typeMisfeed at duplex pre-registration section
JAM code92-01, 92-02, 92-04, 92-40
JAM detection timing92-01: The leading edge of the paper is not turned ON (unblocked) the registration sensor/1 (PS1) even after the lapse of a given period of time after a duplex paper feed sequence has been started.
92-02: For the second-side feed of paper in the duplex mode, loop forming has not been complete before the second side of a sheet enters the registration roller because the rise timing of load to perform registration is earlier than the rise timing of load to form a loop.
92-04: The registration sensor/2 (PS72) is not turned ON even after the lapse of a given period of time after a duplex paper feed sequence has been started.
92-40: For the second-side feed of paper in the duplex mode, the image write start signal permit continues to be disabled for a predetermined period of time after the timing of the image write start signal output.
Paper jam of a sheet of paper left at the duplex pre-registration section results, if a sheet of paper is determined to exist at a position detected when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
Misfeed processing locationRight door
Relevant parts-ADU transport motor/2 (M26)
-Registration sensor/1 (PS1)
-Registration sensor/2 (PS72)
-Base board (BASEB)

Procedure

StepActionControl signalLocation of electrical component
1Initial check items
2PS1 I/O check, sensor checkBASEB CN15E-9 (ON)4-C
3PS72 I/O check, sensor checkBASEB CN15E-19 (ON)5-C
4M26 load check
Check code: 85
Multi code: 6, 9, 10
BASEB CN18E-11 to 146-C
5Replace BASEB. (Part# ACKNH02101)

(Link to the Field Service Manual)