92-01 (bizhub 287/227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
JAM type | Misfeed at duplex pre-registration section | |
JAM code | 92-01 | |
JAM detection timing | The registration sensor (PS1) is not turned ON (unblocked) even after the lapse of a given period of time after a duplex paper feed sequence has been started. | |
– | Paper jam of a sheet of paper left at the duplex pre-registration section results, if a sheet of paper is determined to exist at a position detected when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset. | |
Misfeed processing location | Right door | |
Relevant parts | -ADU transport motor (M5) -Registration sensor (PS1) -MFP board (MFPB) |
Procedure
Step | Action | Control signal | Location of electrical component |
---|---|---|---|
1 | Initial check items | – | – |
2 | PS1 I/O check, sensor check | MFPB CN14E-3 (ON) | 28-C |
3 | M5 operation check | MFPB CN25E-1 to 4 | 17 to 18-C |
4 | Replace MFPB. (Part# A7AHH0201D) | – | – |
- Link to the wiring diagram (bizhub 367/287/227)
K.1.11.1 (Link to the Field Service Manual)