How Can We Help?

92-02 (bizhub 287/227)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

JAM typeMisfeed at duplex pre-registration section
JAM code92-02
JAM detection timingFor the second-side feed of paper in the duplex mode, loop forming has not been complete before the second side of a sheet enters the registration roller because the rise timing of load to perform registration is earlier than the rise timing of load to form a loop.
Paper jam of a sheet of paper left at the duplex pre-registration section results, if a sheet of paper is determined to exist at a position detected when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
Misfeed processing locationRight door
Relevant parts-ADU transport motor (M5)
-Registration sensor (PS1)
-MFP board (MFPB)

 Procedure

StepActionControl signalLocation of electrical component
1Initial check items
2PS1 I/O check, sensor checkMFPB CN14E-3 (ON)28-C
3M5 operation checkMFPB CN25E-1 to 417 to 18-C
4Replace MFPB. (Part# A7AHH0201D)

K.1.11.1 (Link to the Field Service Manual)

Table of Contents