How Can We Help?

92-03 (bizhub C759/C659)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

JAM typeMisfeed at duplex pre-registration section
JAM code92-03
JAM detection timingThe leading edge of the paper does not turn ON the OHP sensor (PS40) even after the lapse of a given period of time after a duplex paper feed sequence has been started.
Misfeed processing location-Upper right door
-Duplex door
Relevant parts-ADU transport motor/1 (M31)
-ADU transport motor/2 (M32)-Registration sensor (PS38)
-OHP sensor (PS40)
-Paper feed/transport drive board (PFTDB)
-MFP board (MFPB)

 Procedure

StepActionControl signalLocation of electrical component
1Initial check items
2PS38 I/O check, sensor checkPFTDB CN2-6 (ON)4-P
3PS40 I/O check, sensor checkPFTDB CN2-2 (DETECT)PFTDB CN2-3 (REM)4-P
4M31 load check
-Check code: 85
-Multi code: 1, 2, 3, 4
PFTDB CN28-14 to 178-P
5M32 load check
-Check code: 85
-Multi code: 5, 6, 7, 8
PFTDB CN28-10 to 137-P
6PFTDB F10 conduction check
7Replace PFTDB. (Part# A795H00200)
8Replace MFPB. (Part# A8JEH02002)

L.1.11.1 (Link to the Field Service Manual)