93-10 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
JAM type | Misfeed at duplex transport section | |
JAM code | 93-10 | |
JAM detection timing | 93-10 | The ADU paper passage sensor/2 (PS48) is not turned ON even after the lapse of a given period of time after the leading edge of the paper has turned ON the ADU paper passage sensor/1 (PS47). |
– | Paper jam of a sheet of paper left at the duplex transport section results, if the ADU paper passage sensor/1 (PS47) is turned ON, or the ADU paper passage sensor/2 (PS48) is turned ON (blocked) when the main power switch ON turned ON, a door is opened and closed, or a misfeed or malfunction is reset. | |
– | Paper jam of a sheet of paper left at the duplex transport section results, if the main power switch is turned ON, the ADU paper passage sensor/1 (PS47) is turned ON. | |
– | Paper jam of a sheet of paper left at the duplex transport section results, if the main power switch is turned ON, the ADU paper passage sensor/2 (PS48) is turned ON. | |
– | Paper jam of a sheet of paper left at the duplex transport section results, if a sheet of paper is determined to exist at a position detected when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset. | |
Misfeed processing location | -Right door -Automatic duplex unit door | |
Relevant parts | -ADU transport motor/1 (M31) -ADU transport motor/2 (M32) -ADU paper passage sensor/1 (PS47) -ADU paper passage sensor/2 (PS48) -Paper feed/transport drive board (PFTDB) -Base board (BASEB) |
Procedure
Step | Action | Control signal | Location of electrical component |
---|---|---|---|
1 | Initial check items | – | – |
2 | PS47 I/O check, sensor check | PFTDB CN28-3 (ON) | 2-P |
3 | PS48 I/O check, sensor check | PFTDB CN28-6 (ON) | 3-P |
4 | M31 load check -Check code: 85 -Multi code: 1, 2, 3, 4 | PFTDB CN28-14 to 17 | 4-P |
5 | M32 load check -Check code: 85 -Multi code: 5, 6, 7, 8 | PFTDB CN28-10 to 13 | 3-P |
6 | PFTDB F25 conduction check. | – | – |
7 | Replace PFTDB. | – | – |
8 | Replace BASEB. | – | – |