Trouble typeC0104: Tray 3/4 feeder transportation motor failure to turn (When PC-417 is installed)

C0105: Tray 3/4 feeder transportation motor turning at abnormal timing (When PC-417 is installed)
RankB
Trouble detection conditionC0104: The control circuit detects motor failure to turn while the motor is turning.

C0105: The control circuit detects motor turning while the motor remains stationary.
Trouble isolationTray 3/4
Relevant electrical parts-Transport motor (M152)
-PC control board (PCCB)

Procedure

  1. Check the connector between M152-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M152 for proper drive coupling and correct as necessary.
  3. M152 load check
    • Check code: 28
    • Multi code: 56, 59, 60
    • Control signal: PCCB CN5-1 to 8
    • Location of electrical component: 7-K
  4. Replace M152. (Part# A7PUM11100)
  5. PCCB F300 conduction check
  6. Replace PCCB. (Part# AAV5H01401)