How Can We Help?

C0106 (bizhub 360i/300i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC0106: Tray 3/transfer LCT paper feed motor turning at abnormal timing (When PC-116, PC-216, or PC-416 is installed)
RankB
Trouble detection condition-The control circuit detects motor failure to turn while the motor is turning.

-The control circuit detects motor turning while the motor remains stationary.
Trouble isolation
Relevant electrical parts<When PC-116 or PC-216 is installed>
-Tray 3 paper feed motor (M111)
-PC control board (PCCB)
<When PC-416 is installed>
-Paper feed motor (M131)
-PC control board (PCCB)

Procedure

When PC-116 or PC-216 is installed

  1. Check the connector between M111-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M111 for proper drive coupling and correct as necessary.
  3. M111 load check
    • Check code: 28
    • Multi code: 11, 14, 15
    • Control signal: PCCB CN5-5 (CW/CCW)
    • Location of electrical component: PC-116/PC-216 4-C
  4. Replace M111. (Part# A2XMM11000)
  5. Replace PCCB.
    PC-116 (Part# AAV5H00101)
    PC-216 (Part# AAV5H00201)

When PC-416 is installed

  1. Check the connector between M131-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M131 for proper drive coupling and correct as necessary.
  3. M131 load check
    • Check code: 28
    • Multi code: 1, 4, 5
    • Control signal: PCCB CN5-5 (CW/CCW)
    • Location of electrical component: PC-416 4-J
  4. Replace M131. (Part# A2XMM11000)
  5. Replace PCCB.(Part# AAV5H00300)

(Link to the Field Service Manual)