Trouble type | C0106: Tray 3/transfer LCT paper feed motor turning at abnormal timing (When PC-116, PC-216, or PC-416 is installed) |
Rank | B |
Trouble detection condition | -The control circuit detects motor failure to turn while the motor is turning. -The control circuit detects motor turning while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | <When PC-116 or PC-216 is installed> -Tray 3 paper feed motor (M111) -PC control board (PCCB) |
<When PC-416 is installed> -Paper feed motor (M131) -PC control board (PCCB) |
Procedure
When PC-116 or PC-216 is installed
- Check the connector between M111-PCCB CN5 for proper connection and correct as necessary.
- Check the connector of M111 for proper drive coupling and correct as necessary.
- M111 load check
- Check code: 28
- Multi code: 11, 14, 15
- Control signal: PCCB CN5-5 (CW/CCW)
- Location of electrical component: PC-116/PC-216 4-C
- Replace M111. (Part# A2XMM11000)
- Replace PCCB.
PC-116 (Part# AAV5H00101)
PC-216 (Part# AAV5H00201)
When PC-416 is installed
- Check the connector between M131-PCCB CN5 for proper connection and correct as necessary.
- Check the connector of M131 for proper drive coupling and correct as necessary.
- M131 load check
- Check code: 28
- Multi code: 1, 4, 5
- Control signal: PCCB CN5-5 (CW/CCW)
- Location of electrical component: PC-416 4-J
- Replace M131. (Part# A2XMM11000)
- Replace PCCB.(Part# AAV5H00300)