C0106 (bizhub C287/C227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0106: Tray 3/LCT paper feed motor turning at abnormal timing (When PC-114, PC-214 or PC-414 is installed) |
Rank | B |
Trouble detection condition | -The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. -The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | <When PC-114 or PC-214 is installed> -Tray 3 paper feed motor (M111) -PC control board (PCCB) |
<When PC-414 is installed> -Paper feed motor (M131) -PC control board (PCCB) |
Procedure
When PC-114 or PC-214 is installed
- Check the connector between M111-PCCB CN5 for proper connection and correct as necessary.
- Check the connector of M111 for proper drive coupling and correct as necessary.
- M111 operation check
- Control signal: PCCB CN5-5 (CW/CCW)
- Location of electrical component: PC-114/PC-214 4-C
- Replace M111. (Part# A7VAM10000)
- Replace PCCB. (PC-114 Part# A7VAH00100 / PC-214 Part# A7VAH00200)
NOTICE
When PC-414 is installed
- Check the connector between M131-PCCB CN5 for proper connection and correct as necessary.
- Check the connector of M131 for proper drive coupling and correct as necessary.
- M131 operation check
- Control signal: PCCB CN5-5 (CW/CCW)
- Location of electrical component: PC-414 5-J
- Replace M131. (Part# A7VAM10000)
- Replace PCCB. (Part# A7VAH00300)
NOTICE
- Link to the wiring diagram (PC-414)
K.3.7.2 (Link to the Field Service Manual)