C0107 (bizhub 368/308)

You are here:

 Contents

Trouble typeC0107: Tray 3/transfer LCT vertical transport motor turning at abnormal timing (When PC-110, PC-210, or PC-410 is installed)
RankB
Trouble detection condition• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Trouble isolation
Relevant electrical parts<When PC-110 or PC-210 is installed>
• Tray 3 vertical transport motor (M112)
• PC control board (PCCB)

<When PC-410 is installed>
• Vertical transport motor (M132)
• PC control board (PCCB)

 Procedure

 When PC-110 or PC-210 is installed

  1. Check the connector between M112-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M112 for proper drive coupling and correct as necessary.
  3. M112 operation check
    • Control signal: PCCB CN5-13 (CW/CCW)
    • Location of electrical component: PC-110/PC-210 3 to 4-C
  4. Replace M112. (Part# A2XMM10000)
  5. Replace PCCB. (PC-110/PC-210) (Part# A2XMH00101/Part# A2XMH00201)

NOTICE

  • Link to the wiring diagram (PC-110)
  • Link to the wiring diagram (PC-210)

 When PC-410 is installed

  1. Check the connector between M132-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M132 for proper drive coupling and correct as necessary.
  3. M132 operation check
    • Control signal: PCCB CN5-13 (CW/CCW)
    • Location of electrical component: PC-410 4-J
  4. Replace M132. (Part# A2XMM10000)
  5. Replace PCCB. (Part# A2XMH00301)

NOTICE

  • Link to the wiring diagram (PC-410)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.7.3 (Link to the Field Service Manual)